SolaHD (Sola Hevi-Duty)
SVL1024100240W 24V DIN PS 85-264VAC
240W 24V DIN PS 85-264VAC
Single-channel AC/DC power supply unit (SMPS PSU) / converter - Emerson / SolaHD Sola/Hevi-Duty (SVL series) - 240W 24V DIN PS 85-264VAC - 10A / 24Vdc / 240W output - Single-phase (1AC) or DC input (100Vac-240Vac (110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac nom.) / 120Vdc-375Vdc (127Vdc / 200Vdc / 220Vdc / 250Vdc nom.)) - screw connections - DIN rail mounting (60mm width) - plastic housing - equivalent to SVL-10-24-100
This product is currently in stock. As availability may change very fast due to demand, please order this product as soon as possible to secure your order availability.
Brand
SKU
SVL1024100
Online Price
$106.32
This product is currently in stock. As availability may change very fast due to demand, please order this product as soon as possible to secure your order availability.
SVL1024100Emerson / SolaHD - SVL series
Description
Single-channel AC/DC power supply unit (SMPS PSU) / converter - Emerson / SolaHD Sola/Hevi-Duty (SVL series) - 240W 24V DIN PS 85-264VAC - 10A / 24Vdc / 240W output - Single-phase (1AC) or DC input (100Vac-240Vac (110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac nom.) / 120Vdc-375Vdc (127Vdc / 200Vdc / 220Vdc / 250Vdc nom.)) - screw connections - DIN rail mounting (60mm width) - plastic housing - equivalent to SVL-10-24-100
Additional Information
Regulated switch mode power supply unit (SMPS PSU) - Sola Hevi-Duti / Sola HD (SVL Essential DIN Rail Series) - Input voltage: 85Vac - 264Vac (100Vac - 240Vac nom.) (single phase input) - Output voltage 24Vdc - Rated current 10A - Rated power 240W - rated for -20C...+70C ambiant with derating
Specifications
Primary brand
Emerson
Secondary brand
SolaHD Sola/Hevi-Duty
Main function
Power supply unit
Product series / family name
SVL series
Functions
Single-channel AC/DC power supply unit (SMPS PSU) / converter
Cooling -- Convection
Cooling -- Convection
Supply voltage (AC)
100Vac-240Vac (110Vac / 120Vac / 200Vac / 208Vac / 220Vac / 230Vac nom.)
85Vac-264Vac
85Vac-264Vac
Supply voltage (DC)
120Vdc-375Vdc (127Vdc / 200Vdc / 220Vdc / 250Vdc nom.)
Display
"DC-OK" green LED
OCP blinking LED
OCP blinking LED
Type of network
Single-phase (1AC) or DC
Rated current
10A output (adjustable)
20A (inrush current at 115Vac input)
40A (inrush current at 230Vac input)
20A (inrush current at 115Vac input)
40A (inrush current at 230Vac input)
Rated power
240W output
Output voltage (DC)
24Vdc output (adjustable)
24Vdc-28Vdc
24Vdc-28Vdc
Connection type
screw connections
Protection functions
Overvoltage protection -- 28.8-35.2V Latching / re-power to recover
Overload protection -- Current fold forward and then hiccup
Over Temperature Protection -- No component damage; latch mode
Short-circuit protection -- Hiccup mode; non-latching (auto-recovery when the fault is removed)
Galvanic isolation
Galvanic isolation -- I/P to O/P -- 3KVac
Galvanic isolation -- I/P to GND -- 2KVac
Galvanic isolation -- O/P to GND -- 0.5KVac
Overload protection -- Current fold forward and then hiccup
Over Temperature Protection -- No component damage; latch mode
Short-circuit protection -- Hiccup mode; non-latching (auto-recovery when the fault is removed)
Galvanic isolation
Galvanic isolation -- I/P to O/P -- 3KVac
Galvanic isolation -- I/P to GND -- 2KVac
Galvanic isolation -- O/P to GND -- 0.5KVac
Efficiency
88% typical
Communication protocol
No communication interface
Mounting mode
DIN rail mounting
Net Height (mm)
123.6 mm
Net Width (mm)
60 mm
Net Depth (mm)
117.6 mm
Weight
950g
Material
plastic housing
Ambient air temperature for operation
-20...+70 °C
Ambient air temperature for storage
-40...+85 °C
Manufacturer product status
Commercialized
Equivalent to
SVL-10-24-100
Compliant with standard(s)
CE Low-Voltage directive (IEC/EN62368-1; CB Certificate IEC/EN 62368-1; IEC/EN 60950-1)
UKCA
cRUus UL Recognized Component ITE (UL 62368-1/CSA C22.2 No. 62368-1; UL 60950-1/CSA C22.2 No. 60950-1)
cRUus UL Recognized Component Hazardous Locations (UL121201/CSA 213 Class I Div 2 Groups A; B; C; D)
cULus Listed Ind. Control Equipment (UL 508; CSA C22.2 No. 107.10)
EMI/RFI emissions -- EN55022 (CISPR22) Class B; EN55011 Class B; EN61000-6-3; EN61000-6-4; EN61000-3-3; EN61204-3; EN61000-3-2 Class A
EMI/RFI immunity -- EN55024; EN61000-6-1; EN61000-6-2 (EN61000-4-2 / -3 / -4 / -5 / -6 / -8 / -11 / -12) Level 3 Performance Criteria A
IEC 60068-2-27 - Shock resistance - 11ms (50G) half-sine pulse; 3 axes (non-operational)
IEC 60068-2-27 - Shock resistance - 11ms (10G) half-sine pulse; 1 axis (operational)
IEC 60068-2-6 - Vibration resistance - 10-500Hz with amplitude of 0.35mm (2G) for 60mins ; 3 axes (operational)
IEC 60068-2-6 - Vibration resistance - 5-500Hz; 2.09G for 20mins; 3 axes (non-operational)
UKCA
cRUus UL Recognized Component ITE (UL 62368-1/CSA C22.2 No. 62368-1; UL 60950-1/CSA C22.2 No. 60950-1)
cRUus UL Recognized Component Hazardous Locations (UL121201/CSA 213 Class I Div 2 Groups A; B; C; D)
cULus Listed Ind. Control Equipment (UL 508; CSA C22.2 No. 107.10)
EMI/RFI emissions -- EN55022 (CISPR22) Class B; EN55011 Class B; EN61000-6-3; EN61000-6-4; EN61000-3-3; EN61204-3; EN61000-3-2 Class A
EMI/RFI immunity -- EN55024; EN61000-6-1; EN61000-6-2 (EN61000-4-2 / -3 / -4 / -5 / -6 / -8 / -11 / -12) Level 3 Performance Criteria A
IEC 60068-2-27 - Shock resistance - 11ms (50G) half-sine pulse; 3 axes (non-operational)
IEC 60068-2-27 - Shock resistance - 11ms (10G) half-sine pulse; 1 axis (operational)
IEC 60068-2-6 - Vibration resistance - 10-500Hz with amplitude of 0.35mm (2G) for 60mins ; 3 axes (operational)
IEC 60068-2-6 - Vibration resistance - 5-500Hz; 2.09G for 20mins; 3 axes (non-operational)
Benefits
Universal input
Short Circuit Protection
Over Voltage Protection
Overload protection
Over Temperature Protection
Power factor correction
Convection Cooling
DC OK LED
Blinking OCP Diagnostic
DC OK Relay for >120 Watts models
2-year limited warranty
Short Circuit Protection
Over Voltage Protection
Overload protection
Over Temperature Protection
Power factor correction
Convection Cooling
DC OK LED
Blinking OCP Diagnostic
DC OK Relay for >120 Watts models
2-year limited warranty
Ripple
100mVpp max.
Application type
Test and measure equipment
Scanners
Instrumentation
Printers peripheral
ATM machines
Vending machines
Semiconductor fabrication equipment
Scanners
Instrumentation
Printers peripheral
ATM machines
Vending machines
Semiconductor fabrication equipment
MTBF (Mean Time Between Failures)
>700 000h (115Vac / 230Vac; at 25°C)
Related Documents
Name | Last Update | Language |
---|---|---|
SolaHD - SVL series - Catalog.pdf | 30 Jan 2022 | English (US) |