Pilz
PILZ-787583PZE X4VP C 3/24Vdc 4N/O fix
PZE X4VP C 3/24Vdc 4N/O fix
Single-channel contact expansion module - SIL3 / PL.d / Cat.3 - Pilz (PNOZ X PZE X4VP) - PZE X4VP C 3/24Vdc 4N/O fix - 20.4-26.4Vdc (24Vdc nom.) supp. voltage - 1 x digital input (24Vdc; 95mA) + 4 x delayed safety outputs (4NO / 4xSPST-NO each made of 2 N.O. contacts in series; 6A 24Vdc DC-1 or 240Vac AC-1 resistive load; 3s fixed time-delay) (17-18; 27-28; 37-38; 47-48) - plug-in/detachable spring term. connections - DIN rail mounting (W22.5mm) - IP40 - rated for -10...+55°C ambient
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
PILZ-787583
Online Price
$289.49
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Pilz - PNOZ X / PZE X4VPPILZ-787583
Description
Single-channel contact expansion module - SIL3 / PL.d / Cat.3 - Pilz (PNOZ X PZE X4VP) - PZE X4VP C 3/24Vdc 4N/O fix - 20.4-26.4Vdc (24Vdc nom.) supp. voltage - 1 x digital input (24Vdc; 95mA) + 4 x delayed safety outputs (4NO / 4xSPST-NO each made of 2 N.O. contacts in series; 6A 24Vdc DC-1 or 240Vac AC-1 resistive load; 3s fixed time-delay) (17-18; 27-28; 37-38; 47-48) - plug-in/detachable spring term. connections - DIN rail mounting (W22.5mm) - IP40 - rated for -10...+55°C ambient
Specifications
Primary brand
Pilz
Main function
Safety relay
Product series / family name
PNOZ X
Sub-range name
PZE X4VP
Functions
Single-channel contact expansion module
Delayed contact expansion
ON-delay de-energization timer
Delayed contact expansion
ON-delay de-energization timer
Supply voltage (DC)
20.4-26.4Vdc (24Vdc nom.)
Display
CH.1 LED indicator
CH.2 LED indicator
CH.2 LED indicator
Rated current
Safety output contacts ratings
6A (24Vdc; DC-1)
6A (240Vac; AC-1)
4A (24Vdc; DC-13)
3A (230Vac; AC-15)
6A (24Vdc; DC-1)
6A (240Vac; AC-1)
4A (24Vdc; DC-13)
3A (230Vac; AC-15)
Connection type
plug-in/detachable spring term. connections
Mounting mode
DIN rail mounting
Operating mode
Single-channel
Digital inputs
1 x digital input (24Vdc; 95mA)
1 x feedback loop input (SPST with 2NC contacts in series) (Y1-Y2)
1 x feedback loop input (SPST with 2NC contacts in series) (Y1-Y2)
Digital outputs
4 x delayed safety outputs (4NO / 4xSPST-NO each made of 2 N.O. contacts in series; 6A 24Vdc DC-1 or 240Vac AC-1 resistive load; 3s fixed time-delay) (17-18; 27-28; 37-38; 47-48)
Degree of protection
IP40
Dimensions
W22.5mm
Net Height (mm)
101 mm
Net Width (mm)
22.5 mm
Net Depth (mm)
121 mm
Material
PPO housing
ABS front housing
ABS front housing
Ambient air temperature for operation
-10...+55 °C
Power consumption
2.5 W
Manufacturer product status
Commercialized
Compliant with standard(s)
EN 60204-1
EN 62061
EN ISO 13849-1
VDE 0113-1
SIL2 / PL.d / Cat.3 (safety contacts delayed <30s)
PFH = 2.48E-09
CE
cULus
EAC
TUV
CCC
EN 62061
EN ISO 13849-1
VDE 0113-1
SIL2 / PL.d / Cat.3 (safety contacts delayed <30s)
PFH = 2.48E-09
CE
cULus
EAC
TUV
CCC
Class
SIL3 / PL.d / Cat.3
Benefits
Positive-guided relay outputs -- 4 safety contacts (N/O); delay-on de-energization
LED display for switch status of the safety contacts
Connection for feedback loop
Operation -- Single-channel
Unit types with various delay times
Plug-in connection terminals (either spring-loaded terminal or screw terminal)
The contact expansion module expands an existing circuit.
As the output relays are monitored via the base unit's feedback loop; the safety functions on the existing circuit are transferred to the contact expansion module.
The safety function remains effective in the case of a component failure.
Earth fault in the feedback loop -- Detected; depending on the base unit that is used.
Earth fault in the input circuit -- The output relays de-energize and the safety contacts open.
LED display for switch status of the safety contacts
Connection for feedback loop
Operation -- Single-channel
Unit types with various delay times
Plug-in connection terminals (either spring-loaded terminal or screw terminal)
The contact expansion module expands an existing circuit.
As the output relays are monitored via the base unit's feedback loop; the safety functions on the existing circuit are transferred to the contact expansion module.
The safety function remains effective in the case of a component failure.
Earth fault in the feedback loop -- Detected; depending on the base unit that is used.
Earth fault in the input circuit -- The output relays de-energize and the safety contacts open.