Pilz
PILZ-787502PNOZ XV2P C 3/24Vdc 2N/O 2N/O t
PNOZ XV2P C 3/24Vdc 2N/O 2N/O t
Single or dual-channel safety relay - SIL1 / PL.c / Cat.1 - SIL3 / PL.e / Cat.4 - SIL2 / PL.d / Cat.3 - Pilz (PNOZ X PNOZ XV2P) - PNOZ XV2P C 3/24Vdc 2N/O 2N/O t - 20.4-26.4Vdc (24Vdc nom.) supp. voltage - 2 x digital inputs (24Vdc; 35mA) (S11-S12; S21-S22; S31-S32) + 2 x instantaneous safety outputs (2NO / 2xSPST-NO each made of 2 N.O. contacts in series; 8A 24Vdc DC-1 or 240Vac AC-1 resistive load) (13-14; 23-24) + 2 x delayed safety outputs (2NO / 2xSPST-NO each made of 2 N.O. contacts in series; 0-3s time-delay selectable 0.1s / 0.2s / 0.3s / 0.4s / 0.5s / 0.6s / 0.7s / 0.8s / 1s / 1.5s / 2s / 3s) (37-38; 47-48) - plug-in/detachable spring term. connections - DIN rail mounting (W45mm) - IP40 - rated for -10...+55°C ambient
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
PILZ-787502
Online Price
$589.95
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Pilz - PNOZ X / PNOZ XV2PPILZ-787502
Description
Single or dual-channel safety relay - SIL1 / PL.c / Cat.1 - SIL3 / PL.e / Cat.4 - SIL2 / PL.d / Cat.3 - Pilz (PNOZ X PNOZ XV2P) - PNOZ XV2P C 3/24Vdc 2N/O 2N/O t - 20.4-26.4Vdc (24Vdc nom.) supp. voltage - 2 x digital inputs (24Vdc; 35mA) (S11-S12; S21-S22; S31-S32) + 2 x instantaneous safety outputs (2NO / 2xSPST-NO each made of 2 N.O. contacts in series; 8A 24Vdc DC-1 or 240Vac AC-1 resistive load) (13-14; 23-24) + 2 x delayed safety outputs (2NO / 2xSPST-NO each made of 2 N.O. contacts in series; 0-3s time-delay selectable 0.1s / 0.2s / 0.3s / 0.4s / 0.5s / 0.6s / 0.7s / 0.8s / 1s / 1.5s / 2s / 3s) (37-38; 47-48) - plug-in/detachable spring term. connections - DIN rail mounting (W45mm) - IP40 - rated for -10...+55°C ambient
Specifications
Primary brand
Pilz
Main function
Safety relay
Product series / family name
PNOZ X
Sub-range name
PNOZ XV2P
Functions
Single or dual-channel safety relay
Safety gate monitoring
Instantaneous E-STOP (Emergency stop) monitoring
Limit switch monitoring
Delayed E-STOP monitoring
Monitored manual reset
Safety gate monitoring
Instantaneous E-STOP (Emergency stop) monitoring
Limit switch monitoring
Delayed E-STOP monitoring
Monitored manual reset
Supply voltage (DC)
20.4-26.4Vdc (24Vdc nom.)
Display
Power LED indicator
Start LED indicator
CH.1 LED indicator
CH.2 LED indicator
CH.1 [t] LED indicator
CH.2 [t] LED indicator
Start LED indicator
CH.1 LED indicator
CH.2 LED indicator
CH.1 [t] LED indicator
CH.2 [t] LED indicator
Rated current
Safety output contacts ratings
8A (24Vdc; DC-1)
8A (240Vac; AC-1)
7A (24Vdc; DC-13)
5A (230Vac; AC-15)
8A (24Vdc; DC-1)
8A (240Vac; AC-1)
7A (24Vdc; DC-13)
5A (230Vac; AC-15)
Connection type
plug-in/detachable spring term. connections
Protection functions
2 operating modes (with or without detection of shorts across contacts)
Mounting mode
DIN rail mounting
Operating mode
Single-channel operation -- No redundancy in the input circuit -- earth faults in the start and input circuit are detected.
Dual-channel operation -- with detection of shorts across contacts / Redundant input circuit -- detects earth faults in the start and input circuit; short circuits in the input circuit; shorts across contacts in the input circuit.
Automatic start -- Unit is active once the input circuit has been closed.
Monitored start -- Unit is active once the input circuit is closed and once the start circuit is closed after the waiting period has elapsed
Increase in the number of available contacts by connecting contact expansion modules or external contactors/relays.
Dual-channel operation -- with detection of shorts across contacts / Redundant input circuit -- detects earth faults in the start and input circuit; short circuits in the input circuit; shorts across contacts in the input circuit.
Automatic start -- Unit is active once the input circuit has been closed.
Monitored start -- Unit is active once the input circuit is closed and once the start circuit is closed after the waiting period has elapsed
Increase in the number of available contacts by connecting contact expansion modules or external contactors/relays.
Digital inputs
2 x digital inputs (24Vdc; 35mA) (S11-S12; S21-S22; S31-S32)
1 x start input (S13-S14; S33-S34)
1 x reset input (Y39-Y40)
1 x start input (S13-S14; S33-S34)
1 x reset input (Y39-Y40)
Digital outputs
2 x instantaneous safety outputs (2NO / 2xSPST-NO each made of 2 N.O. contacts in series; 8A 24Vdc DC-1 or 240Vac AC-1 resistive load) (13-14; 23-24)
2 x delayed safety outputs (2NO / 2xSPST-NO each made of 2 N.O. contacts in series; 0-3s time-delay selectable 0.1s / 0.2s / 0.3s / 0.4s / 0.5s / 0.6s / 0.7s / 0.8s / 1s / 1.5s / 2s / 3s) (37-38; 47-48)
2 x delayed safety outputs (2NO / 2xSPST-NO each made of 2 N.O. contacts in series; 0-3s time-delay selectable 0.1s / 0.2s / 0.3s / 0.4s / 0.5s / 0.6s / 0.7s / 0.8s / 1s / 1.5s / 2s / 3s) (37-38; 47-48)
Degree of protection
IP40
Dimensions
W45mm
Net Height (mm)
101 mm
Net Width (mm)
45 mm
Net Depth (mm)
121 mm
Material
PPO housing
ABS front housing
ABS front housing
Ambient air temperature for operation
-10...+55 °C
Power consumption
4.5 W
Manufacturer product status
Commercialized
Compliant with standard(s)
EN 60947-5-1
EN 60204-1
EN 62061
EN ISO 13849-1
VDE 0113-1
SIL1 / PL.c / Cat.1 (safety contact delayed ≥30s)
SIL3 / PL.e / Cat.4 (instantaneous safety contacts)
SIL2 / PL.d / Cat.3 (safety contact delayed <30s)
PFH = 2.31E-09 (instantaneous safety contact)
PFH = 2.64E-09 (safety contact delayed <30s)
PFH = 2.87E-09 (safety contact delayed ≥30s)
CE
cULus
EAC
TUV
CCC
EN 60204-1
EN 62061
EN ISO 13849-1
VDE 0113-1
SIL1 / PL.c / Cat.1 (safety contact delayed ≥30s)
SIL3 / PL.e / Cat.4 (instantaneous safety contacts)
SIL2 / PL.d / Cat.3 (safety contact delayed <30s)
PFH = 2.31E-09 (instantaneous safety contact)
PFH = 2.64E-09 (safety contact delayed <30s)
PFH = 2.87E-09 (safety contact delayed ≥30s)
CE
cULus
EAC
TUV
CCC
Class
SIL1 / PL.c / Cat.1
SIL3 / PL.e / Cat.4
SIL2 / PL.d / Cat.3
SIL3 / PL.e / Cat.4
SIL2 / PL.d / Cat.3
Benefits
Positive-guided relay outputs -- 2 safety contacts (N/O); instantaneous / 2 safety contacts (N/O); delay-on de-energization
Connection options for E-STOP pushbutton / Safety gate limit switch / Start button
LED display for supply voltage / Switch state of the safety contacts / Start circuit
Delay time fixed or selectable
Possible to cancel delay time
Plug-in connection terminals (either spring-loaded terminal or screw terminal)
The circuit is redundant with built-in self-monitoring.
The safety function remains effective in the case of a component failure.
The correct opening and closing of the safety function relays is tested automatically in each on-off cycle.
Connection options for E-STOP pushbutton / Safety gate limit switch / Start button
LED display for supply voltage / Switch state of the safety contacts / Start circuit
Delay time fixed or selectable
Possible to cancel delay time
Plug-in connection terminals (either spring-loaded terminal or screw terminal)
The circuit is redundant with built-in self-monitoring.
The safety function remains effective in the case of a component failure.
The correct opening and closing of the safety function relays is tested automatically in each on-off cycle.
Related Documents
Name | Last Update | Language |
---|---|---|
Pilz - PNOZ XV2P - Manual.pdf | 14 Oct 2021 | English (US) |