Pilz
PILZ-778010PMUT X1P 24Vdc 3N/O 1N/C 5so
PMUT X1P 24Vdc 3N/O 1N/C 5so
Dual-channel sfty. rly. / muting unit - SIL3 / PL.e / Cat.4 - Pilz - PMUT X1P 24Vdc 3N/O 1N/C 5so - 24Vdc supp. voltage - 5 x digital inputs (24Vdc; 25mA) (S11-S12; S21-S22; S31-S32; S51-S52; S61-S62) + 3 x instantaneous safety outputs (3NO / 3xSPST-NO each made of 2 N.O. contacts in series; 8A 24Vdc DC-1 or 240Vac AC-1 resistive load) (13-14; 23-24; 33-34) + 1 x instantaneous aux. output (1NC / SPST-NC made of 2 N.C. contacts in parallel) (41-42) + 5 x digital outputs (semiconductor; 24Vdc; 20mA) (Y32; Y36) - plug-in/detachable screw term. connections - 90mm width - Plug-in - PPO housing - IP40 - rated for -10...+55°C ambient
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
PILZ-778010
Online Price
$904.47
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Pilz - PNOZ X / PMUT X1PPILZ-778010
Description
Dual-channel sfty. rly. / muting unit - SIL3 / PL.e / Cat.4 - Pilz - PMUT X1P 24Vdc 3N/O 1N/C 5so - 24Vdc supp. voltage - 5 x digital inputs (24Vdc; 25mA) (S11-S12; S21-S22; S31-S32; S51-S52; S61-S62) + 3 x instantaneous safety outputs (3NO / 3xSPST-NO each made of 2 N.O. contacts in series; 8A 24Vdc DC-1 or 240Vac AC-1 resistive load) (13-14; 23-24; 33-34) + 1 x instantaneous aux. output (1NC / SPST-NC made of 2 N.C. contacts in parallel) (41-42) + 5 x digital outputs (semiconductor; 24Vdc; 20mA) (Y32; Y36) - plug-in/detachable screw term. connections - 90mm width - Plug-in - PPO housing - IP40 - rated for -10...+55°C ambient
Specifications
Primary brand
Pilz
Main function
Muting unit
Functions
Dual-channel sfty. rly. / muting unit
Muting lamps monitoring
Instantaneous E-STOP (Emergency stop) monitoring
Parallel / sequential muting
Muting lamps monitoring
Instantaneous E-STOP (Emergency stop) monitoring
Parallel / sequential muting
Supply voltage (DC)
24Vdc
Display
Power LED indicator
S1 LED indicator
S2 LED indicator
S1+S2 LED indicator
Output LED indicator
ML Fault LED indicator
CH.1 LED indicator
CH.2 LED indicator
S1 LED indicator
S2 LED indicator
S1+S2 LED indicator
Output LED indicator
ML Fault LED indicator
CH.1 LED indicator
CH.2 LED indicator
Rated current
Safety output contacts ratings
8A (24Vdc; DC-1)
8A (240Vac; AC-1)
5A (24Vdc; DC-13)
5A (240Vac; AC-15)
8A (24Vdc; DC-1)
8A (240Vac; AC-1)
5A (24Vdc; DC-13)
5A (240Vac; AC-15)
Connection type
plug-in/detachable screw term. connections
Protection functions
2 operating modes (with or without detection of shorts across contacts)
Mounting mode
Plug-in
Operating mode
Dual-channel operation (contact or semiconductor outputs from ESPE) -- without detection of shorts across contacts
Dual-channel operation (contact or semiconductor outputs from ESPE) -- with detection of shorts across contacts. Redundant input circuit; earth faults in the input circuit or shorts across the input circuits are detected.
Monitored manual start -- The supply voltage must be presented and the safety circuits closed before the start contact is closed. The unit is not active until the start button has been operated once the waiting period has expired (see technical details)
The muting controller can be used for parallel (with 2 muting sensors) or sequential muting
Dual-channel operation (contact or semiconductor outputs from ESPE) -- with detection of shorts across contacts. Redundant input circuit; earth faults in the input circuit or shorts across the input circuits are detected.
Monitored manual start -- The supply voltage must be presented and the safety circuits closed before the start contact is closed. The unit is not active until the start button has been operated once the waiting period has expired (see technical details)
The muting controller can be used for parallel (with 2 muting sensors) or sequential muting
Digital inputs
5 x digital inputs (24Vdc; 25mA) (S11-S12; S21-S22; S31-S32; S51-S52; S61-S62)
1 x digital input (for additional sfty. light grid) (LA-; LA+; LB-; LB+)
1 x digital input (for additional sfty. light grid) (LA-; LA+; LB-; LB+)
1 x digital input (start input) (S33-S34)
1 x digital input (restart input) (S43-S44)
1 x digital input (for additional sfty. light grid) (LA-; LA+; LB-; LB+)
1 x digital input (for additional sfty. light grid) (LA-; LA+; LB-; LB+)
1 x digital input (start input) (S33-S34)
1 x digital input (restart input) (S43-S44)
Digital outputs
3 x instantaneous safety outputs (3NO / 3xSPST-NO each made of 2 N.O. contacts in series; 8A 24Vdc DC-1 or 240Vac AC-1 resistive load) (13-14; 23-24; 33-34)
1 x instantaneous aux. output (1NC / SPST-NC made of 2 N.C. contacts in parallel) (41-42)
5 x digital outputs (semiconductor; 24Vdc; 20mA) (Y32; Y36)
1 x instantaneous aux. output (1NC / SPST-NC made of 2 N.C. contacts in parallel) (41-42)
5 x digital outputs (semiconductor; 24Vdc; 20mA) (Y32; Y36)
Degree of protection
IP40
Dimensions
90mm width
Net Height (mm)
94 mm
Net Width (mm)
90 mm
Net Depth (mm)
121 mm
Material
PPO housing
ABS front housing
ABS front housing
Ambient air temperature for operation
-10...+55 °C
Power consumption
33 W
Manufacturer product status
Commercialized
Compliant with standard(s)
EN 60204-1
EN ISO 13849-1
VDE0113-1
SIL3 / PL.e / Cat.4
PFH = 3.01E-09
EN 61496-1
CE
cULus
EAC
TUV
CCC
EN ISO 13849-1
VDE0113-1
SIL3 / PL.e / Cat.4
PFH = 3.01E-09
EN 61496-1
CE
cULus
EAC
TUV
CCC
Class
SIL3 / PL.e / Cat.4
Benefits
Positive-guided relay outputs -- 3 safety contacts (N/O); instantaneous / 1 auxiliary contact (N/C); instantaneous
4 inputs for muting sensors
1 ESPE input for light grids (2-channel; contact or semiconductor outputs)
1 input for additional safety light grid (2-channel; contact outputs) or safety contacts
Connection option for 2 muting lamps
Connection options for start button / key switch / feedback loop
5 semiconductor outputs
Monitors muting lamps
Muting mode -- sequential or parallel
LED display for switch status channel 1/2 / muting sensors / light grid / simultaneity requirement / muting lamp error
Semiconductor outputs signal -- Switch state of the safety contacts / Muting active / One of the muting lamps defective / Both muting lamps defective / Light grid (ESPE) active
Plug-in connection terminals (either spring-loaded terminal or screw terminal)
See order reference for unit types
The circuit is redundant with built-in self-monitoring.
The safety function remains effective in the case of a component failure.
The correct opening and closing of the safety function relays is tested automatically in each on-off cycle.
4 inputs for muting sensors
1 ESPE input for light grids (2-channel; contact or semiconductor outputs)
1 input for additional safety light grid (2-channel; contact outputs) or safety contacts
Connection option for 2 muting lamps
Connection options for start button / key switch / feedback loop
5 semiconductor outputs
Monitors muting lamps
Muting mode -- sequential or parallel
LED display for switch status channel 1/2 / muting sensors / light grid / simultaneity requirement / muting lamp error
Semiconductor outputs signal -- Switch state of the safety contacts / Muting active / One of the muting lamps defective / Both muting lamps defective / Light grid (ESPE) active
Plug-in connection terminals (either spring-loaded terminal or screw terminal)
See order reference for unit types
The circuit is redundant with built-in self-monitoring.
The safety function remains effective in the case of a component failure.
The correct opening and closing of the safety function relays is tested automatically in each on-off cycle.
Application type
for muting lamp monitoring
for emergency STOP monitoring
for emergency STOP monitoring