Single-channel safety relay - SIL3 / PL.e / Cat.4 - Pilz (PNOZsigma PNOZ s2) - PNOZ s2 24Vdc 3N/O 1N/C - 20.4-26.4Vdc (24Vdc nom.) supp. voltage - 1 x digital input (24Vdc; 75mA) + 3 x instantaneous safety outputs (3NO / 3xSPST-NO each made of 2 N.O. contacts in series; 6A 24Vdc DC-1 or 240Vac AC-1 resistive load) (13-14; 23-24; 33-34) + 1 x instantaneous aux. output (1NC / SPST-NC made of 2 N.C. contacts in series) (41-42) + 1 x aux. output (semiconductor output (1SO); 24Vdc; 20mA) (Y32) - plug-in/detachable screw term. connections - DIN rail mounting (W17.5mm) - IP40 - rated for -10...+55°C ambient
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
PILZ-750102
Online Price
$241.11
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Pilz - PNOZsigma / PNOZ s2PILZ-750102
Description
Single-channel safety relay - SIL3 / PL.e / Cat.4 - Pilz (PNOZsigma PNOZ s2) - PNOZ s2 24Vdc 3N/O 1N/C - 20.4-26.4Vdc (24Vdc nom.) supp. voltage - 1 x digital input (24Vdc; 75mA) + 3 x instantaneous safety outputs (3NO / 3xSPST-NO each made of 2 N.O. contacts in series; 6A 24Vdc DC-1 or 240Vac AC-1 resistive load) (13-14; 23-24; 33-34) + 1 x instantaneous aux. output (1NC / SPST-NC made of 2 N.C. contacts in series) (41-42) + 1 x aux. output (semiconductor output (1SO); 24Vdc; 20mA) (Y32) - plug-in/detachable screw term. connections - DIN rail mounting (W17.5mm) - IP40 - rated for -10...+55°C ambient
Specifications
Primary brand
Pilz
Main function
Safety relay
Product series / family name
PNOZsigma
Sub-range name
PNOZ s2
Functions
Single-channel safety relay
Safety gate monitoring
Instantaneous E-STOP (Emergency stop) monitoring
Limit switch monitoring
Monitored manual reset
Safe separation
Safety gate monitoring
Instantaneous E-STOP (Emergency stop) monitoring
Limit switch monitoring
Monitored manual reset
Safe separation
Supply voltage (DC)
20.4-26.4Vdc (24Vdc nom.)
Display
Power LED indicator
In1 LED indicator
In2 LED indicator
Output LED indicator
Reset LED indicator
Fault LED indicator
In1 LED indicator
In2 LED indicator
Output LED indicator
Reset LED indicator
Fault LED indicator
Rated current
Safety output contacts ratings
6A (24Vdc; DC-1)
6A (240Vac; AC-1)
5A (24Vdc; DC-13)
5A (230Vac; AC-15)
6A (24Vdc; DC-1)
6A (240Vac; AC-1)
5A (24Vdc; DC-13)
5A (230Vac; AC-15)
Connection type
plug-in/detachable screw term. connections
Mounting mode
DIN rail mounting
Operating mode
Single-channel operation -- No redundancy in the input circuit -- earth faults in the start and input circuit are detected.
Automatic start -- Unit is active once the input circuit has been closed.
Manual start -- Unit is active once the input circuit and the start circuit are closed.
Monitored start -- with falling edge -- Unit is active once the input circuit is closed and then the start circuit is closed and opened again. The start circuit is closed and then opened again once the input circuit is closed.
Monitored start -- with rising edge -- Unit is active once the input circuit is closed and once the start circuit is closed after the waiting period has elapsed
Increase in the number of available instantaneous safety contacts by connecting contact expander modules or external contactors/relays; A connector can be used to connect 1 PNOZsigma contact expansion module.
Automatic start -- Unit is active once the input circuit has been closed.
Manual start -- Unit is active once the input circuit and the start circuit are closed.
Monitored start -- with falling edge -- Unit is active once the input circuit is closed and then the start circuit is closed and opened again. The start circuit is closed and then opened again once the input circuit is closed.
Monitored start -- with rising edge -- Unit is active once the input circuit is closed and once the start circuit is closed after the waiting period has elapsed
Increase in the number of available instantaneous safety contacts by connecting contact expander modules or external contactors/relays; A connector can be used to connect 1 PNOZsigma contact expansion module.
Digital inputs
1 x digital input (24Vdc; 75mA)
1 x reset/start input (S34)
1 x reset/start input (S34)
Digital outputs
3 x instantaneous safety outputs (3NO / 3xSPST-NO each made of 2 N.O. contacts in series; 6A 24Vdc DC-1 or 240Vac AC-1 resistive load) (13-14; 23-24; 33-34)
1 x instantaneous aux. output (1NC / SPST-NC made of 2 N.C. contacts in series) (41-42)
1 x aux. output (semiconductor output (1SO); 24Vdc; 20mA) (Y32)
1 x instantaneous aux. output (1NC / SPST-NC made of 2 N.C. contacts in series) (41-42)
1 x aux. output (semiconductor output (1SO); 24Vdc; 20mA) (Y32)
Degree of protection
IP40
Dimensions
W17.5mm
Net Height (mm)
98 mm
Net Width (mm)
17.5 mm
Net Depth (mm)
120 mm
Material
PC housing
Ambient air temperature for operation
-10...+55 °C
Power consumption
2 W
Manufacturer product status
Commercialized
Compliant with standard(s)
EN 60947-5-1
EN 60204-1
EN 62061
EN ISO 13849-1
VDE 0113-1
SIL3 / PL.e / Cat.4
PFH = 2.50E-09
CE
cULus
EAC
TUV
KOSHA
CCC
EN 60204-1
EN 62061
EN ISO 13849-1
VDE 0113-1
SIL3 / PL.e / Cat.4
PFH = 2.50E-09
CE
cULus
EAC
TUV
KOSHA
CCC
Class
SIL3 / PL.e / Cat.4
Benefits
Positive-guided relay outputs -- 3 safety contacts (N/O); instantaneous / 1 auxiliary contact (N/C); instantaneous
Protective separation of safety contacts from all other circuits
1 semiconductor output
Connection options for E-STOP pushbutton / Safety gate limit switch / Start button
A connector can be used to connect 1 PNOZsigma contact expansion module
Operating modes can be set via rotary switch
LED indicator for supply voltage / Input status; channel 1 / Input status; channel 2 / Switch status of the safety contacts / Start circuit / Errors
Plug-in connection terminals (either spring-loaded terminal or screw terminal)
The circuit is internally redundant with built-in self-monitoring.
The safety device remains effective in the case of a component failure.
The correct opening and closing of the safety device relays is tested automatically in each on-off cycle.
Protective separation of safety contacts from all other circuits
1 semiconductor output
Connection options for E-STOP pushbutton / Safety gate limit switch / Start button
A connector can be used to connect 1 PNOZsigma contact expansion module
Operating modes can be set via rotary switch
LED indicator for supply voltage / Input status; channel 1 / Input status; channel 2 / Switch status of the safety contacts / Start circuit / Errors
Plug-in connection terminals (either spring-loaded terminal or screw terminal)
The circuit is internally redundant with built-in self-monitoring.
The safety device remains effective in the case of a component failure.
The correct opening and closing of the safety device relays is tested automatically in each on-off cycle.