ABB
2TLA022202R2000FII-4-30-1050
FII-4-30-1050
Safety light curtain (transmitt. + receiv. pair) for hands protection - SIL3 PLe Cat4 Type4 - ABB Jokab (Focus II series) - Type FII-4-30-1050 - 1050mm protected height - 0.2m-14m operating distance - 30mm resolution / beams pitch - 2 x digital outputs (PNP; 24Vdc; 0.5A) - Supply voltage 24Vdc - Infrared (IR) light (880nm) - with 5-pin M12 (M12-5) male connector (transmitt.) + 8-pin M12 (M12-8) male connector (receiv.) - Yellow - Aluminium (housing) / Polycarbonate (front/end cap) / Polyamide (connector) - IP65 - Rated for -10°C...+55°C - Compliant with ENISO12100-1; ENISO13849-1; EN62061; EN60204-1; EN61496-1; EN60664-1; EN61000-6-2; EN61000-6-4 standards
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
Brand
SKU
2TLA022202R2000
Please add this item to cart to request a quote.
Please add this item to cart to request a quote or contact us at [email protected] for product availability.
2TLA022202R2000ABB / Jokab - Focus II series
Description
Safety light curtain (transmitt. + receiv. pair) for hands protection - SIL3 PLe Cat4 Type4 - ABB Jokab (Focus II series) - Type FII-4-30-1050 - 1050mm protected height - 0.2m-14m operating distance - 30mm resolution / beams pitch - 2 x digital outputs (PNP; 24Vdc; 0.5A) - Supply voltage 24Vdc - Infrared (IR) light (880nm) - with 5-pin M12 (M12-5) male connector (transmitt.) + 8-pin M12 (M12-8) male connector (receiv.) - Yellow - Aluminium (housing) / Polycarbonate (front/end cap) / Polyamide (connector) - IP65 - Rated for -10°C...+55°C - Compliant with ENISO12100-1; ENISO13849-1; EN62061; EN60204-1; EN61496-1; EN60664-1; EN61000-6-2; EN61000-6-4 standards
Specifications
Primary brand
ABB
Secondary brand
Jokab
Main function
Safety light curtain
Product series / family name
Focus II series
Functions
Safety light curtain (transmitt. + receiv. pair) for hands protection
LED indicator
Manual reset
Automatic reset
Pre reset
Muting inputs
Muting lamp supervision
Override
Muting T/L/X
Blanking 3 types
Single/Double break
EDM
LED indicator
Manual reset
Automatic reset
Pre reset
Muting inputs
Muting lamp supervision
Override
Muting T/L/X
Blanking 3 types
Single/Double break
EDM
Distance
30mm resolution / beams pitch
Supply voltage (DC)
24Vdc
Sensing distance
0.2m-14m
Light Color
Infrared (IR)
Wavelength
880 nm
Color
Yellow
Connection type
5-pin M12 (M12-5) male connector (transmitt.)
8-pin M12 (M12-8) male connector (receiv.)
8-pin M12 (M12-8) male connector (receiv.)
Digital outputs
2 x digital outputs (PNP; 24Vdc; 0.5A)
Degree of protection
IP65
Dimensions
1050mm protected height
Material
Aluminium (housing)
Polycarbonate (front/end cap)
Polyamide (connector)
Polycarbonate (front/end cap)
Polyamide (connector)
Ambient air temperature for operation
-10°C...+55 °C
Ambient air temperature for storage
-25°C...+70 °C
Manufacturer product status
Commercialized
Compliant with standard(s)
ENISO12100-1
ENISO13849-1
EN62061
EN60204-1
EN61496-1
EN60664-1
EN61000-6-2
EN61000-6-4
CE
TUV
cCSAus
EN ISO 12100-1 (2010)
EN ISO 13849-1 (2008)
EN 62061 (2005)
EN 60204-1 (2007) + A1 (2009)
EN 61496-1 / AC (2010)
EN 60664-1 (2007)
EN 61000-6-2 (2005)
EN 61000-6-4 (2007)
ENISO13849-1
EN62061
EN60204-1
EN61496-1
EN60664-1
EN61000-6-2
EN61000-6-4
CE
TUV
cCSAus
EN ISO 12100-1 (2010)
EN ISO 13849-1 (2008)
EN 62061 (2005)
EN 60204-1 (2007) + A1 (2009)
EN 61496-1 / AC (2010)
EN 60664-1 (2007)
EN 61000-6-2 (2005)
EN 61000-6-4 (2007)
Class
SIL3
PLe
Cat4
Type4
PLe
Cat4
Type4
Application type
Optical protection in an opening or around a hazardous area
Related Documents
Name | Last Update | Language |
---|---|---|
ABB - Jokab - Products list.pdf | 13 Jan 2020 | English (US) |
ABB - Jokab machine safety products - Catalogue.pdf | 13 Jan 2020 | English (US) |